Influence of sub-nanosecond time of flight resolution for online range verification in proton therapy using the line-cone reconstruction in Compton imaging

Résumé

Online ion range monitoring in hadron therapy can be performed via detection of secondary radiation, such as prompt γ-rays, emitted during treatment. The prompt γ emission profile is correlated with the ion depth-dose profile and can be reconstructed via Compton imaging. The line-cone reconstruction, using the intersection between the primary beam trajectory and the cone reconstructed via a Compton camera, requires negligible computation time compared to iterative algorithms. A recent report hypothesised that time of flight (TOF) based discrimination could improve the precision of the γ fall-off position (FOP) measured via line-cone reconstruction, where TOF comprises both the proton transit time from the phantom entrance until γ emission, and the flight time of the γ-ray to the detector. The aim of this study was to implement such a method and investigate the influence of temporal resolution on the precision of the FOP. Monte Carlo simulations of a 160 MeV proton beam incident on a homogeneous PMMA phantom were performed using GATE. The Compton camera consisted of a silicon-based scatterer and CeBr3 scintillator absorber. The temporal resolution of the detection system (absorber + beam trigger) was varied between 0.1 and 1.3 ns rms and a TOF-based discrimination method applied to eliminate unlikely solution(s) from the line-cone reconstruction. The FOP was obtained for varying temporal resolutions and its precision obtained from its shift across 100 independent γ emission profiles compared to a high statistics reference profile. The optimal temporal resolution for the given camera geometry and 108 primary protons was 0.2 ns where a precision of 2.30 ± 0.15 mm (1σ) on the FOP was found. This precision is comparable to current state-of-the-art Compton imaging using iterative reconstruction methods or 1D imaging with mechanically collimated devices, and satisfies the requirement of being smaller than the clinical safety margins. (IOP)
Fichier principal
Vignette du fichier
Livingstone+et+al_2021_Phys._Med._Biol._10.1088_1361-6560_ac03cb.pdf (1.21 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03257804 , version 1 (14-06-2021)

Identifiants

Citer

Jayde Livingstone, Denis Dauvergne, A. Etxebeste, Mattia Fontana, Marie-Laure Gallin-Martel, et al.. Influence of sub-nanosecond time of flight resolution for online range verification in proton therapy using the line-cone reconstruction in Compton imaging. Physics in Medicine and Biology, 2021, 66, pp.125012. ⟨10.1088/1361-6560/ac03cb⟩. ⟨hal-03257804⟩
127 Consultations
75 Téléchargements

Altmetric

Partager

More